Mains electricity and safety
Mains electricity is very useful but can kill, so homes are designed with safety features: insulation, earth wires, fuses, circuit breakers and RCDs. The mains is alternating current at about 230 V (50 Hz) in South Africa and the UK, and 120 V (60 Hz) in the USA – far more than the 1.5 V of a cell.
Key facts
- International (IEC) colours: live = brown, neutral = blue, earth = green and yellow.
- The live wire carries the alternating voltage; the neutral completes the circuit; the earth only carries current if there is a fault.
- A fuse melts if the current is too big. Choose the smallest fuse just above the normal current: I = P ÷ V.
- Earthing: if a metal case becomes live, a large current flows to earth and blows the fuse.
- Double-insulated appliances (plastic case) need no earth wire.
- An RCD cuts the supply in milliseconds if the live and neutral currents differ (typically by 30 mA).
Worked examples
Example 1
A 2300 W kettle runs on 230 V. Fuses come in 3 A, 5 A and 13 A. Which should it have?
- Use P = IV, so I = P ÷ V I = 2300 ÷ 230 = 10 A
- The fuse must be just above 10 A: 13 A.
Answer: 13 A
Example 2
The metal case of a washing machine becomes live because of a loose wire. Explain how the earth wire and fuse protect the user.
- The earth wire joins the metal case to the ground with very low resistance.
- A big current flows from live, through the case, down the earth wire.
- This current is far above the fuse rating, so the fuse melts and disconnects the live wire.
- The case is no longer live, so touching it is safe.
Answer: A large current flows through the earth wire, the fuse melts and the supply is cut off.
Example 3
A 13 A extension lead on 230 V is used for a 2000 W heater and a 1200 W hairdryer at the same time. Is this safe?
- Total power 2000 + 1200 = 3200 W
- Current I = 3200 ÷ 230 ≈ 13.9 A
- 13.9 A > 13 A, so the fuse would blow (or the lead overheat).
Answer: No – the total current is about 13.9 A, more than 13 A.